Jin Xinqiao
CVs of Prof. Jin Xinqiao (X.Q. Jin)
+8621 - 3420 6774
xqjin [at] sjtu.edu.cn
|
Education
B.S., Refrigeration and Cryogenics, 1987, Shanghai Jiao Tong University, China
M.S., Refrigeration and Cryogenics, 1990, Shanghai Jiao Tong University, China
Ph.D., Refrigeration and Cryogenics, 2000, Shanghai Jiao Tong University, China
|
Fields of Interest
Simulation of building and HVAC systems
Optimal control of refrigeration and air conditioning systems
Energy conversation for operation
Management of HVAC systems
FDD and FTC of HVAC and control system
Summary
Dr. Xinqiao JIN was promoted to Associate Professor in Dec. 1999, and then to full Professor in Dec. 2005. He is currently the deputy director of Committee of Heat Pump and HVAC of Shanghai Society of Refrigeration, a member of National Standard Committee, a consultant of Government Purchasing of Jiangsu Province. Prof. Jin has published more than 100 journal papers; 20 of which are accepted by international journals. He is the reviewer of several international journals includingEnergy and buildings, Energy Conversion and ManagementandHVACR Research.
Prof. JIN has conducted many research projects sponsored by National Science Foundation of China, International Cooperation projects, China Post Doctor Science Foundation, National Defense Science and Industry Committee etc. He also has projects going with industry partners such as many famous companies including UTRC, Carrier, and DAIKIN.
Selected Awards
1.The Shanghai Science and Technology Advancement Award, (2nd Prize, Rank 6), 2004, “Research on disinfection equipments for central air conditioning system”, granted by Shanghai Government
2.Science and Technology Progress Award of Shanghai (3rd Prize, Rank 3), 2000, “Absorption-diffusion NH3-H2O refrigerator”, granted by Shanghai Government
3.The Scientific and Technological Progress Award (3rd Prize, Rank 3), 1999, “Test rig of FDD system for refrigeration system”, granted by Ministry of Education, China
Selected Research Projects
1.X.Q.Jin, Z.M. Du, Study on tolerant control and energy evaluation in HVAC systems, RMB 350,000, 2010-2012,National Natural Science Foundation projects (NSFC)
2.Z.M. Du,X.Q.Jin, Multiple faults diagnosis and tolerant control efficiency in HVAC systems, RMB 200,000, 2011-2013,National Natural Science Foundation projects (NSFC)
3.X.Q.Jin, Z.M. Du, Simulation system of ocean environment. RMB2,280,000, 2009-2011,CSSC
4.Z.M. Du,X.Q.Jin, Multiple faults tolerant control based on model and data in HVAC systems, RMB 50,000,2007-2009 China Postdoctoral Science Foundation
5.X.Q. Jin, Study on the Performance of Air Heat Exchangers in Wet Conditions(I~V), RMB1,900,000, 2006-2011, Daikin
6..X.Q. Jin, Numerical Simulation and Experiment on Ceiling Air-Diffuse, RMB560,000, 2006-2007, Daikin
Selected Patents
1.Z.M. Du,X.Q. Jin, C. Yang, P Chen, W.B. Zhang, An gas-liquid mixing machine for heat pumps, Applied, 2010
2.Z.M. Du,X.Q. Jin, X.B. Yang, A high efficient drawer-type water heat exchanger. Applied, 2010
3.Z.M. Du,X.Q. Jin, X.F. Chai, H. Meng, An VAV outdoor air optimal controller,to be licensed, CN101266464, 2009
4.X.Q. Jin, Z.M. Du, An economic outdoor air controller, CN1888673, 2008
5.X.Q. Jin, Z.M. Du, An energy-saving HVAC system, CN1888614, 2008
6.X.Q. Jin, J.C. Pan, Z.M. Du, A transpiration-cooled constant temperature and humidity machine. ZL2006 1 0026846.8, 2006
Selected Publications
●B. Fan,X.Q. Jin, Z.M. Du, A Hybrid FDD Strategy For Local System Of AHU Based On Artificial Neural Network And Wavelet Analysis,Building and Environment, 2010, 45 (7): 2698-2708
●Z.M. Du,X.Q. Jin, Y.Y. Yang, Fault diagnosis for temperature, flow rate and pressure sensors in VAV systems using wavelet neural network,Applied Energy,2009, 86(9): 1624-1631
●Z.M. Du,X.Q. Jin, A robot fault diagnostic tool for flow rate sensors in air dampers and VAV terminals,Energy and Buildings, 2009, 41(3): 279-286
●Z.M. Du,X.Q. Jin, Wavelet neural network-based fault diagnosis in air-handling units,HVACR Research, 2008, 14(6): 959-973. US
●X.Q. Jin, Z.M. Du , Energy Evaluation of Optimal Control Strategies for Central VWV Chiller Systems,Applied Thermal Engineering, 2007, 27: 934-941
●Z.M. Du,X.Q. Jin, Lizhou Wu, PCA-FDA-based fault diagnosis for sensors in VAV systems,HVACR Research, 2007, 13(2): 349-367
●Z.M. Du,X.Q. Jin, Detection and diagnosis for multiple faults in VAV systems,Energy and Buildings, 2007, 39(8): 923-934
●X.Q. Jin, Z.M. Du, X.K. Xiao, Fault tolerant control of outdoor air and AHU supply air temperature in VAV air conditioning systems using PCA method,Applied Thermal Engineering, 2006, 26(11-12): 1226-1237